It is suitable for various surgeries on cuting or coagulation, including general surgery, heart, gynecology, anorectal surgery, orthopedics
thoracic surgery, tumor, etc.
It is suitable for various surgeries on cuting or coagulation, including general surgery, heart, gynecology, anorectal surgery, orthopedics thoracic surgery, tumor, etc.It is also used with surgeries of endoscope, hysteroscope, laparoscope, ENT endoscope, etc. The bipolar can be used in the fine surgeries of microsurgery, neurology, ENT and ophthalmology, hand surgery, etc.
Mono Cut | Cutting: 400W | Blend: 150W |
Mono Coag | Soft Coag: 100W | Strong Coag:80W |
Bipolar | Bipolar Coag: 50W | |
Ambient temperature range: 10°C~40°C | Relative humidity range: 30%~75% | |
Atmospheric pressure range: 700hpa~1060hpa | Power supply: 220V/110V, 50Hz | |
Working frequency: 360kHz~460kHz | Type of equipment: CF | |
The power consumption of the whole device is less than 1000VA. (Cutting function: 400W) |
Independent output port of endoscope and inteligent conversion key, which can enter endoscopic mode automatically after start-up.
Microcomputer control system, power-off protection, and memory function of keeping last usage data after restart.
Automatic adjustment on output power. t can be adjusted automaticaly according to the change of density of tissue. Stable output power to keepthe minimum wastage.
Automatic conversion on monopolar and bipolar.
Automatic monitoring of on-off, automatic detection and error prompt in work.
The monitoring circuit system on contact qually of neutral electrode can test and evaluate the safty and efectiveness on the contact area betweerelectrode plate and skin. The system can cut off output automatically and give an alamm, in case of finding that contact area is in dangerous level. itcan test and use negative plate of monopolar or bipolar effectively.
Operating panel with keys, high defniion and large digital. t has diferent sound and light indicators duing operation. Waterproof operating keys easyto clean and maintain.
Independent three-way power output. This increases the convenience and security of operation.
It can be operated and performed well underwater even when dissecting and removal of fat tissue.
Fuly suspended power output. There are two independent and isolated application sections to prevent defbrilalion interference (monopolar and bipolar).
Delivery within 3-15 days after receipt of payment, delivery may be a little later for large or customized products, but not much later.
Yes, the sample freight needs to be paid by the customer.
Most of our products are available for OEM & ODM with your logo and design. For more details, leave us a message via Whatsapp, or Mail.